INTRAVASCULAR ULTRASOUND DERIVED MINIMAL LUMINAL AREA AND PLAQUE BURDEN OF CORONARY VESSELS IN OUR LOCAL POPULATION

Main Article Content

Muhammad Ishaq Khan , Abid Ullah , Rafiullah Jan , Shafi Ullah

Abstract

Objectives: To report the average IVUS derived MLAs and plaque burden of coronary arteries of our local population.


Methodology: It was a retrospective observational study. A total of 64 patients having IVUS done from January 2022 to September 2022 was enrolled in this study. IVUS images were acquired using 40 MHz, 3.1 French Opticross IVUS catheter (OptiCross™, Boston Scientific, USA).


Results: Out of 54 patients, 39 (72%) were males with a mean age of 53.7 ± 14.1 years. The left main (LM) disease was found in n = 43 (79.6%) on coronary angiogram. The LM mean minimal luminal area was 6.68 ± 1.9 mm2 and mean minimal luminal diameter was 3.83 mm ± 1.02. Mean LM plaque burden was 57% (range 0-57). In proximal LAD mean MLA was 5.04 ± 2.7mm2, mean proximal reference diameter was 3.97 ± 0.64 mm and plaque burden was 53.88 ± 16.5%. The pattern of the plaque was diffuse with more calcified in the LAD than in the left main stem. The mean minimal stent area achieved in patients who had received stenting was 13.05 ± 2.88mm2 in LM (n = 15), and 9.71 ± 2.88 mm2 in proximal LAD (n = 30).

Article Details

Section
Articles